TMR 32x8 DDCS
32x8 Double Digital Cross Connect System
Provides blocking cross connection up to 992 of 64Kbit/s channels in form of 32 E1 in pairs using up to 248 of 64Kbit/s channels in form of 8 E1 in pairs
Product Overview
- Offers blocked full cross connect functionality to cross connect between the double of 32 inports and 8 outports.
- Aggregate DS-0s, \"n\"x64Kbps consecutive data channels and fractional E1 channels to full E1 channels
- E1 Monitoring interface monitors an E1 signal through a Hi-Z path, without in any way disturbing the live E1 traffic that is required to be monitored.
- Both receive and transmit directions of E1 can be monitored simultaneously in pairs.
- Combine traffic from partially utilized facilities onto a single fully utilized E1.
- Remote access through Ethernet for management and configuration
- Occupies only a 3U high rack space, and is complete 19-inch stand alone unit that provides connectivity for up to double of 32 in and 8 out E1.
- The unit operates an a -48Vdc input power supply (AC input adapter is optional for AC mains operations)
32 x8 Double Digital Cross Connect System
Switches 992 of 64Kbit/s channels in form of 32 E1 in pairs to 248 of 64Kbit/s channels in form of 8 E1 in pairs
Core System
- 19 inch Chassis
- Control Card with Serial and LAN management ports
- 48 Vdc input Power Supply Card
- Back Plane with Reglets
- GUI- Configuration Software
- User Manual
Extendable Units
- 8 in 2 out E1 Interface Card (maximum 8)
- 32 in 8 out 2 Mbps Memory Time Switch Card (maximum 2)
Optional Units
- 220Vac to -48Vdc Converter
Technical Specifications
INPUTS (E1 Lines to be Monitored)
- Impedance Hi-Z;G.772
- Pulse Shape Compliance G.703
- Framing G.704
- Number of E1 ports 32 pairs
OUTPUTS
- Impedance120 ohms
- Pulse Shape Compliance G.703
- Signal Pulse 3.0 Volt as per G.703
- Framing G.704
- Number of E1 ports8 pairs
E1 Interface
- Line Rate E1(2.048 Mbps +/- 50 bps)
- Available Time Slots 1-31
- Framing G.704
- Electrical G.703
- Jitter G.823
- Impedance 120 ohms
Management and Control
- 10/100 BaseT Telnet over TCP/IP Network
Power Supply
- Power Supply -48Vdc(-40Vdc to 60Vdc)
- Power Consumption 20 Watts (max)
Chassis
- 3U height
- 19 inch Rack Mounting Shelf
Programmable Features
- Selecting the source of synchronization
- Specifying the priority sequence for clock selection
- Enabling and disabling E1 ports (masking the not used E1 ports)
- Creating cross connect between E1s at DS-0 level(single time slot level is 64 Kbps)
- Specifying run time log level
- Telnet interface for remote programming
- Establishing different type of loops on E1 ports for test and maintenance purposes
Indications & Alarms
- Loss and AIS of incoming signal at any E1 port
- Configuration Error Alarm
- Clock Status
- 2 LED indicators to indicate the status of each E1 port
- +3.3 Vdc Power Supply
- -48Vdc Present
- Ethernet Status
Status Monitoring
- Source Clock of Synchronization
- Status of E1 Alarms: LOS,AIS, LFA…
- Enabled /Disabled status of E1 ports
- Input connection table of any E1 output
- Output connection table of any E1 input
- Error Counters
|